Power equipment for the multi-functional pump control valve integrates three valve types: a gate valve, a check valve, and a water hammer eliminator. Each valve performs a different function during pump operation, supporting stable and reliable control.
Product Description
A multifunctional pump control valve comprises a main valve, a regulating valve, and a receiver (auxiliary) system. The valve body uses a DC-type design. The main valve control chamber is configured as a diaphragm-type or piston-type double control chamber structure. Compared with conventional hydraulic control valves, the control chamber is one additional chamber, which enhances the control functions of the main valve and enables multifunctional regulation of the pump outlet, including slow opening, full opening, slow closing, and stopping. These functions are achieved through a single valve and a single adjustment, providing multifunctional pump control.
This product is used in high-rise building water supply systems and other water supply pump outlet pipeline applications. It prevents and attenuates water hammer caused by pump start-up and shut-down, prevents backflow to protect the pump, and helps maintain pipeline safety. To achieve pump operation automation, reduce manual valve operation, simplify management, lower labor input, and improve reliability, hydraulic valves and electric valves are used to replace manual valves. Through a series of technical improvements to traditional monoblock valves, slow-opening and slow-closing backstop valves, slow-acting hydraulic open/close valves, automatic slow-closing gate valves, and double-speed self-closing valves (and other valve types) have been developed.
Product Detail Drawing
Product Basic Functions
Gate Valve
The gate valve is normally kept in a closed position. When the pump starts, the gate valve is opened slowly. When the pump stops, the gate valve closes quickly first, and then continues to close slowly after the flow has decreased to a certain level. The controlled “closed gate” start-up and “closed gate” shut-down can effectively prevent pump outlet water hammer and suppress the water hammer impact. At the same time, it reduces motor load during pump start-up. Under minimum shaft power conditions (at approximately zero flow rate), the shaft power is generally about 30% of the design shaft power. Another function of the gate valve is that when it is closed, it provides safe isolation conditions for valves and pumps installed between the gate valve and the pump—such as backstop valves—helping prevent backflow from the pressure pipeline.
Check Valve
The check valve prevents water flow reversal caused by sudden power failure and helps avoid backflow. Sudden pump shut-down is prone to water hammer. When the pump’s static head is high, the instantaneous high pressure generated by severe water hammer may cause pipe rupture and result in serious production accidents.
Water Hammer Eliminator
The water hammer eliminator can effectively eliminate destructive fluid shocks in the transmission system without requiring flow interruption. In the event of irregular water hammer and surges, it prevents water shock waves from damaging the pipeline and provides protection. Therefore, to mitigate water hammer damage, a water hammer eliminator is commonly installed on the pump pressure water pipeline.
STORAEN’s control valve redefines industrial fluid management by combining three critical functions—gate valve isolation, check valve backflow prevention, and water hammer elimination—into a single, space-saving design. Engineered to replace traditional multi-valve configurations, our flow control valve and water pressure control valve solutions simplify pipeline systems while improving safety and efficiency. They are ideal for high-rise water supply, industrial pumping stations, and utility networks.
1. Integrated Gate Valve: Precise Flow Isolation
At the core of this multifunctional control valve is a heavy-duty gate valve mechanism, providing reliable on/off control for maintenance or emergency shutdowns:
Full-Bore Passage: A parallel gate design (DN50–DN1400) ensures minimal pressure loss (≤0.01MPa) and unrestricted flow when fully open, offering [reference] energy efficiency benefits of about 20% compared with conventional gate valves.
Dual-Seat Sealing: Soft rubber or metal-to-metal seals (depending on the media) provide bubble-tight shutoff, which is critical for isolating pumps or pipelines during repairs without residual flow risks.
2. Built-In Check Valve: Automatic Backflow Protection
Eliminating the need for a separate check valve, the design features a spring-loaded disc that closes instantly when flow reverses, protecting pumps from damaging backflow:
Low-Crack Pressure Design: The disc opens at approximately 0.05MPa to support stable forward flow in low-pressure systems, while closing within about 0.2 seconds of flow reversal—faster than standalone check valves by [reference] approximately 30%.
Particle Resistance: A streamlined valve body reduces debris accumulation, making it suitable for water containing small solids (e.g., sand and scale) without compromising sealing performance.
3. Advanced Water Hammer Eliminator: Controlled Closure Technology
The third integrated function addresses the “silent killer” of pipelines—water hammer—using a dual-control chamber system:
Slow-Shut Mechanism: A diaphragm or piston-type control chamber (user-selectable pressure control valve types) adjusts the closure time from 3–120 seconds, suppressing water hammer peaks to ≤1.5× working pressure (compared with 3× in traditional setups [reference]).
Three-Stage Operation:
Fast Closure of the Main Disc (80% stroke within 5s) to arrest high-velocity flow;
Gradual Closure of the Pilot Valve (remaining 20% over 30–120s) to eliminate pressure surges;
Automatic locking in the closed position to prevent backflow during pump shut-downs.
Tailored to Your Fluid Control Needs
Whether managing a high-rise water distribution network or an industrial cooling system, our water control valves and flow control valve types provide versatile performance. The integrated design not only simplifies maintenance but also enhances system reliability by removing potential failure points between separate valves.
Upgrade to STORAEN’s control valve solution and benefit from three critical functions in one robust package—engineered to protect pipelines, extend pump service life, and streamline operations. Explore our pressure control valve types today and discover why smarter fluid management begins with integrated innovation.
In STORAEN’s control valve designs, selecting between diaphragm and piston-type control chambers is critical to achieving precise pressure regulation and stable flow control. As two primary pressure control valve types, each offers distinct advantages tailored to specific industrial needs. Below is an overview of how they work and where they excel.
1. Diaphragm Control Chambers: Smooth, Low-Noise Regulation for Clean Media
Ideal for water supply, HVAC, and low-particle systems, diaphragm chambers use a flexible EPDM or NBR membrane to translate pressure into motion:
Operation Principle: Upstream pressure acts on the diaphragm and pushes it downward to adjust the valve disc position. A return spring balances the force, enabling stepless flow modulation with minimal hysteresis (≤1.5% of full scale).
Key Benefits:
Cost-Effective & Leak-Proof: No mechanical seals or moving parts exposed to the media helps reduce maintenance by [reference] about 20% and eliminates contamination risks in potable water or pharmaceutical lines.
Quiet Operation: The soft membrane absorbs vibration, making it suitable for noise-sensitive environments such as high-rise buildings (noise ≤65 dB during operation [reference]).
Limitations & [Reference] Performance Data: Best suited for pressures up to 6.3 MPa and temperatures from -10°C to 80°C; not recommended for abrasive fluids. Commonly used in our water pressure control valve and flow control valve models for municipal applications.
2. Piston Control Chambers: Heavy-Duty Performance for High-Pressure, Harsh Media
For industrial processes involving high pressure, high temperatures, or particle-laden fluids (e.g., wastewater and oil), piston chambers provide robust mechanical control:
Operation Principle: A cylindrical piston (cast iron or 316L stainless steel) converts hydraulic or pneumatic pressure into linear motion, directly actuating the valve stem with high torque (up to 500 N·m [reference]).
Key Benefits:
Extreme Pressure Resistance: Handles up to 10.0 MPa and temperatures up to 150°C, offering [reference] superior performance versus diaphragms by about 60% in high-pressure applications such as industrial boiler systems.
Abrasion Tolerance: A hard-chrome-plated piston surface resists scratches from sand, scale, or sludge, supporting 50,000+ cycle life in abrasive environments—critical for mining or chemical plants [reference].
Design Notes: Includes a double-directional mechanism to prevent lateral movement, minimizing seat wear and maintaining sealing accuracy (leakage ≤0.01% of rated flow [reference]).
When to Choose Diaphragm vs Piston?
Media Type: Diaphragm for clean liquids/gases; piston for dirty fluids, high-viscosity media (e.g., lubricating oil), or steam.
Control Precision: Diaphragm provides finer adjustment (0.5% resolution [reference]); piston prioritizes power and durability.
Industry Fit:
Diaphragm: Water distribution and building automation (water control valve applications).
Piston: Petrochemical, power generation, and heavy industry (paired with our flow control valve types for process pipelines).
STORAEN’s Engineered Excellence
Customization Options: Both designs comply with control valve sizing standards (ISO 5208, GB/T 17213), with configurable stroke lengths (25–300 mm) and feedback sensors (4–20 mA) for automated systems [reference].
Reliability Upgrades: Diaphragms include anti-tear aramid reinforcement; pistons incorporate self-lubricating PTFE rings, reducing friction by [reference] about 30% compared with generic models.
Make the Right Choice for Your System
Whether you need the precision of a diaphragm or the ruggedness of a piston, STORAEN’s control valve solutions provide optimal pressure regulation for your operating conditions. By understanding these core technologies, you can select the appropriate pressure control valve type to improve efficiency, reduce downtime, and meet the most demanding industrial requirements. Contact us today to explore how our engineering expertise can enhance your fluid control system.
Principles of Construction
Working Principle
(1) When the pump is stopped, the valve plate closes at the outlet end and the upper chamber of the diaphragm under static pressure.
(2) When the pump starts, water pressure is transmitted into the lower chamber from the bypass pipe. At the inlet end and lower chamber, the main valve plate and the slow-closing valve plate open slowly under the action of water pressure.
(3) Under the pressure at the inlet end, the valve plate rises to the maximum opening state. The opening height is determined by the flow rate.
(4) Immediately when the pump stops, the flow rate and pressure drop suddenly. The main valve plate starts to move downward under the action of gravity.
(5) When the flow rate is close to zero, the main valve is closed. The main valve plate remains on the relief openings to weaken the impact of water hammer. The pressure difference between the lower and upper chambers is formed, and the valve outlet water pressure from the bypass pipe is introduced into the upper cavity to actuate the diaphragm pressure plate. As a result, the lower cavity water discharges into the valve inlet, and the slow-closing valve plate begins slow closure.
(6) The slow-closing valve plate fully closes the drain opening, and the valve returns to the initial state for pump operation.
Basic structure
The overall size of the valve is comparable to that of a conventional check valve and comprises a main valve and external accessories. The main valve includes a valve body, a pressure plate, a diaphragm, a large valve plate, a slow-closing valve plate, a valve seat, a stem assembly, and other components. The slow-closing valve plate is connected to the pressure plate and diaphragm via the stem assembly. The diaphragm is clamped between the valve cover and the diaphragm seat, and the up-and-down movement of the diaphragm drives the slow-closing valve plate to move up and down.
The valve stem passes through the center opening of the large valve plate, allowing the large valve plate to slide along the valve stem within a specified range. Normally, the large valve plate is pressed onto the valve seat by its own weight, keeping the valve in the closed state. Multifunctional pump control valve external accessories are installed on both sides of the valve diaphragm and on the valve inlet and outlet pipes. The lower chamber of the diaphragm and the connecting pipe at the valve inlet side are equipped with control valves, filters, and a special backstop valve.
The upper diaphragm cavity and the valve on the outlet-side connecting pipe are equipped only with a filter and a control valve. The movement and position of the large valve plate and the slow-closing valve plate within the main valve determine changes in the valve operating status and opening/closing performance. The external accessories and piping upstream and downstream of the valve introduce pressure changes to the valve divided into the upper and lower chambers, controlling the movement of the large valve plate and the slow-closing valve plate. By adjusting the accessories, the opening speed and slow-closing time of the large valve plate and the slow-closing valve plate can be set within the specified range.
Working Pressure
This type of multifunctional pump control valve has working pressures of 1.0 MPa, 1.6 MPa, 2.5 MPa, 4.0 MPa, 6.4 MPa, and 10.0 MPa. The actuation (pilot) pressure is greater than or equal to 0.03 MPa. The media temperature range is 0–80°C. The slow-closing time is adjustable from 3–120 s. For a pipeline flow velocity of 2 m/s, the pressure loss is less than 0.01 MPa [reference], and the peak water hammer pressure is less than 1.5× the working pressure [reference]. Nominal diameters: DN50–DN1400.
|
DN |
L |
H |
D |
D1 |
D2 |
n-Φd |
|||||||||||
|
PN1.0 |
PN1.6 |
PN2.5 |
PN1.0 |
PN1.6 |
PN2.5 |
PN1.0 |
PN1.6 |
PN2.5 |
PN1.0 |
PN1.6 |
PN2.5 |
||||||
40 |
240 |
395 |
150 |
150 |
150 |
110 |
110 |
110 |
84 |
84 |
84 |
4-18 |
4-18 |
4-18 |
|||
50 |
240 |
395 |
165 |
165 |
165 |
125 |
125 |
125 |
99 |
99 |
99 |
4-18 |
4-18 |
4-18 |
|||
65 |
250 |
405 |
185 |
185 |
185 |
145 |
145 |
145 |
118 |
118 |
118 |
4-18 |
4-18 |
8-18 |
|||
80 |
285 |
430 |
200 |
200 |
200 |
160 |
160 |
160 |
1132 |
132 |
132 |
8-18 |
8-18 |
8-18 |
|||
100 |
360 |
510 |
220 |
220 |
235 |
180 |
180 |
190 |
156 |
156 |
156 |
8-18 |
8-18 |
8-22 |
|||
125 |
400 |
560 |
250 |
250 |
270 |
210 |
210 |
220 |
184 |
184 |
184 |
8-18 |
8-18 |
8-26 |
|||
150 |
455 |
585 |
285 |
285 |
300 |
240 |
240 |
250 |
211 |
211 |
211 |
8-22 |
8-22 |
8-26 |
|||
200 |
585 |
675 |
340 |
340 |
360 |
295 |
295 |
310 |
266 |
266 |
274 |
8-22 |
12-22 |
12-26 |
|||
250 |
650 |
730 |
395 |
405 |
425 |
350 |
355 |
370 |
319 |
319 |
330 |
12-22 |
12-26 |
12-30 |
|||
300 |
800 |
760 |
445 |
460 |
485 |
400 |
410 |
430 |
370 |
370 |
389 |
12-22 |
12-26 |
16-30 |
|||
350 |
860 |
840 |
505 |
520 |
555 |
460 |
470 |
490 |
429 |
429 |
448 |
16-22 |
16-26 |
16-33 |
|||
400 |
960 |
910 |
565 |
580 |
620 |
515 |
525 |
550 |
480 |
480 |
503 |
16-26 |
16-30 |
16-36 |
|||
450 |
1075 |
1030 |
615 |
640 |
670 |
565 |
585 |
600 |
530 |
548 |
548 |
20-26 |
20-30 |
20-36 |
|||
500 |
1075 |
1135 |
670 |
715 |
760 |
620 |
650 |
660 |
585 |
582 |
609 |
20-26 |
20-33 |
20-36 |
|||
600 |
1230 |
1270 |
780 |
840 |
845 |
725 |
770 |
770 |
685 |
682 |
720 |
20-30 |
20-36 |
20-39 |
|||
700 |
1650 |
1460 |
895 |
910 |
960 |
840 |
840 |
875 |
794 |
794 |
820 |
24-30 |
24-36 |
24-42 |
|||
Main installation dimensions: (Unit: mm)
A control valve is a key component in many industrial and manufacturing processes. Its primary function is to regulate fluid flow within a system. These valves are essential for maintaining the required operating conditions in pipelines, tanks, and other fluid-handling facilities. For professionals in engineering, manufacturing, and process management, understanding the function of a control valve is critical.
The main purpose of a control valve is to modulate the flow rate of a fluid (liquid or gas) according to defined operating parameters. This is achieved by adjusting its position in response to signals from a controller—either a manual operator or an automated control system. Through this adjustment, the valve helps keep process variables such as pressure, temperature, and flow rate within predefined limits.
Control valves use various mechanisms to perform their function. Common valve types include globe, ball, and butterfly valves, each designed for different flow-control applications. By enabling precise control of flow characteristics, control valves contribute significantly to improved efficiency and safety in industrial operations.
In addition, the correct operation of control valves directly affects system performance and reliability. When these valves function as intended, they help prevent issues such as pressure surges, flow instability, and leaks. Conversely, malfunctioning control valves may cause costly downtime, safety risks, and compromised product quality.
In summary, the function of a control valve is to ensure accurate and efficient regulation of fluid flow across a wide range of applications. Their role is essential for maintaining optimal operating conditions, improving energy efficiency, and protecting overall system integrity. Therefore, understanding and implementing effective control valve strategies is important for achieving operational excellence in any fluid-processing environment.
Control valves are essential components in many industrial processes. They regulate fluid flow by varying the size of the flow passage based on control signals. Understanding the different types of control valves and their applications helps optimize system performance and support operational safety.
One primary type of control valve is the globe valve, known for its excellent throttling capabilities. It has a spherical valve body that allows controlled flow and is typically used for steam, water, and air applications in power plants and chemical processing units.
Another common type is the ball valve, characterized by fast shut-off performance. It uses a rotating ball to control flow and is commonly applied where tight sealing and minimal pressure drop are required, such as in water treatment facilities and oil and gas pipelines.
Butterfly valves are also widely used across a range of applications, offering both on/off and throttling service. Their compact design and lightweight construction make them suitable for high-flow, large-volume applications such as HVAC systems and water distribution networks.
For precise control and fast response in automated systems, electromagnetic control valves are frequently used. These valves operate using electrical signals and are commonly found in irrigation systems and industrial automation applications.
Finally, globe-style control valves provide enhanced performance for critical duties that require accurate flow regulation. They are often implemented in demanding environments such as chemical manufacturing and petroleum refineries, where precise control is essential.
In summary, choosing the right control valve depends on the specific requirements of the application, including flow characteristics, acceptable pressure drops, and operational efficiency. Understanding the various control valve types and their applications can significantly improve reliability and efficiency—making control valves an important part of any industrial process.